Furnace size calculator (BTU)

Enter your heated floor area, the age of the house and your region to get a rule-of-thumb heat loss and the common furnace sizes that cover it. Use it to sense-check a quote; a CSA F280 room-by-room load calculation is the proper sizing method in Canada.

Estimate your furnace size

Estimates update as you change the inputs. Nothing is sent anywhere.

sq ft

All above-grade floors you heat. A listing or your house plans usually show it. Add a finished basement below.

Home age and insulation
Where the home is

Counted at about half the above-grade rate.

Estimated heat loss on the coldest days

61,000 to 72,000 BTU/h

Rule of thumb for your inputs

Ticks mark the output of common furnace sizes, labelled by input.

Output to aim for

about 66,500 BTU/h

Nearest common size

80,000 BTU/h input

About 76,800 BTU/h output at 96%

A 60,000 BTU/h input furnace (about 57,600 output) falls just short of this range. A load calculation decides between the two.

  • Above grade1,800 sq ft × 34 to 40

A CSA F280 room-by-room load calculation is the proper sizing method in Canada.

Get A Free Quote

Get the real number for your home: a free, no-obligation quote.

Rule of thumb only: 25 to 45 BTU/h per sq ft depending on age and insulation, calibrated for southern and eastern Ontario. Homes in Northern Ontario, and any home with major additions or renovations, need a measured load calculation.

On this page
  1. Input BTU and output BTU are different numbers
  2. Why a bigger furnace is not better
  3. How this calculator works it out
  4. Worked example
  5. What a proper load calculation looks at
  6. Questions people ask

Input BTU and output BTU are different numbers

Furnace size is quoted as input: the gas it burns per hour, in BTU/h. What heats your home is output, input multiplied by efficiency. A 96% furnace turns 60,000 BTU/h of input into about 57,600 BTU/h of heat; a 1990s mid-efficiency furnace at about 80% delivers only 48,000 from the same input. So copying the number on your old furnace's label is a mistake: the same input in a new high-efficiency furnace is already a step up in heat.

Common furnace sizes: input and approximate output
InputOutput at about 96%Output at about 80% (older mid-efficiency)
40,000 BTU/h38,40032,000
60,000 BTU/h57,60048,000
80,000 BTU/h76,80064,000
100,000 BTU/h96,00080,000
120,000 BTU/h115,20096,000
Bright open-plan living and dining room with large windows
Photo: Francesca Tosolini on Unsplash

Why a bigger furnace is not better

An oversized furnace reaches the thermostat setting quickly, shuts off and restarts a few minutes later. That short cycling brings temperature swings, noisy blasts of hot air, more starts on the igniter and inducer, and less time at steady, efficient output. Ducts sized for a smaller furnace can struggle with the extra airflow: whistling registers and shutdowns on the high-limit switch are the signs.

Many older Ontario homes have furnaces bigger than they need. The first one was often sized generously, the house has since gained insulation, better windows and air sealing, and each replacement copied the old label. Two-stage and modulating furnaces soften the problem because they spend most of the winter on low, but they are no reason to skip proper sizing. Settle the size first, then check typical Ontario furnace prices for the type you want.

Central air changes the answer

The furnace blower also moves air for the air conditioner, roughly 400 cubic feet per minute per ton of cooling. A 3-ton AC needs about 1,200 CFM, which can rule out the smallest furnaces even when the heat loss is low. The AC size calculator covers the cooling side.

How this calculator works it out

  1. Heat loss per square foot

    Age and insulation pick a band inside the 25 to 45 BTU/h per sq ft rule of thumb (table below).

  2. Climate and basement

    Central and eastern Ontario adds about 10%. A finished, heated basement counts at about half the above-grade rate, because the soil around it stays far warmer than winter air.

  3. Output and size

    The middle of the range is the output to aim for, because the rule of thumb is already generous. The tool picks the smallest common input size whose output, at about 96%, covers it, and names the next size up only when that pick falls short of the top of the range.

Heat-loss rule of thumb by home age, southern Ontario
Home age and insulationBTU/h per sq ftFor 1,800 sq ft
Newer and airtight25 to 3045,000 to 54,000
1990s to 2010s29 to 3552,000 to 63,000
1960s to 1980s34 to 4061,000 to 72,000
Before 1960 or drafty39 to 4570,000 to 81,000

Worked example

A 2,000 sq ft two-storey house in London, built in 1995, with an unfinished basement. The 1990s to 2010s band gives 29 to 35 BTU/h per sq ft, so the heat loss estimate is 58,000 to 70,000 BTU/h. Southwestern Ontario needs no climate adjustment.

The output to aim for is about 64,000 BTU/h, the middle of that range, and the smallest common furnace that covers it is 80,000 BTU/h input (about 76,800 output). Furnaces come in steps of about 20,000 BTU/h, so the pick can land well above the middle. A 60,000 input furnace (about 57,600 output) falls just short. That is the decision a room-by-room load calculation should settle: if the house measures below about 57,600 BTU/h, the smaller furnace fits better and usually costs less. The furnace cost calculator prices either size.

What a proper load calculation looks at

A CSA F280 calculation works room by room instead of using one number for the house. Ontario's building code points to it for sizing heating in new houses, and it is good practice for replacements.

  • Each room separately, so every room gets the right airflow
  • Insulation in the walls, attic and basement, and the window area and type in each room
  • Air leakage, ideally from a blower door test if the home has had an energy assessment
  • The winter design temperature for your town, several degrees colder in Ottawa or Barrie than in Windsor
  • Ducts that run through unheated spaces such as an attic, garage or crawlspace

Ask for the heat-loss figure in writing with each quote, and if two installers recommend different sizes, ask each to show the number behind it. The furnace price guide and furnace buying guide cover what else to compare.

Get a quote sized for your home

Ask for a free in-home estimate from a participating local heating and cooling company, and ask them to show the heat-loss number behind the size they recommend.

Get A Free Quote

Free, no obligation. About a minute to request.

Questions people ask

What size furnace do I need for a 2,000 sq ft house in Ontario?

By the 25 to 45 BTU/h per sq ft rule of thumb, a 2,000 sq ft home loses about 50,000 to 90,000 BTU/h on the coldest days, depending on age and insulation. That points to furnaces between 60,000 and 100,000 BTU/h input. A tight, well-insulated home often measures lower, which is why a load calculation matters before you choose.

What is the difference between furnace input and output BTU?

Input is the gas the furnace burns per hour; output is the heat it delivers to your ducts. Output equals input times efficiency. A 96% furnace rated at 80,000 BTU/h input delivers about 76,800 BTU/h. An older 80% furnace with a 100,000 input delivers about 80,000, nearly the same heat as the smaller new furnace.

Can I size a furnace from the old one?

Only as a starting point. Many older furnaces were oversized to begin with, and the house may have had insulation, window or air sealing upgrades since. A new high-efficiency furnace also delivers more heat per BTU of input than an old mid-efficiency one. Ask the installer for a heat-loss calculation rather than a nameplate match.

One visit turns the range into a price

A participating local heating and cooling company checks the house and puts the price in writing. Free, with no obligation to buy.

Get A Free Quote

Free, no obligation. About a minute to request.